Frankfurt Am Main, Stadt, Hesse
Job Summary

Job Summary : Responsible for managing end-to-end shift operations of the data center ensuring SLA adherence, operational continuity, and compliance with security and regulatory standards. Acts as the primary escalation point for incidents, leads technical execution of complex IMAC activities, and ensures smooth coordination across teams, vendors, and stakeholders.

ob Description : DC Technician (L2)\\\\r\\\\nLocation: Frankfurt (Onsite)\\\\r\\\\nExperience: 5–7 Years \\\\r\\\\n\\\\r\\\\nRole Summary\\\\r\\\\nResponsible for managing end-to-end shift operations of the data center ensuring SLA adherence, operational continuity, and compliance with security and regulatory standards. Acts as the primary escalation point for incidents, leads technical execution of complex IMAC activities, and ensures smooth coordination across teams, vendors, and stakeholders.\\\\r\\\\nKey Responsibilities\\\\r\\\\n• Own and manage shift-level operations ensuring 24x7 service availability and adherence to SLA/KPI targets\\\\r\\\\n• Act as the primary escalation point for incidents (P1/P2/P3) and ensure timely response and resolution\\\\r\\\\n• Monitor liquid cooling systems including CDUs, piping loops, pumps, and rack-level cooling distribution units on a 24x7 basis.\\\\r\\\\n• Activities including coolant quality checks, pressure verification, and leak detection validation.\\\\r\\\\n• Respond to liquid cooling alarms including pressure drops, flow inconsistencies, and temperature deviation events and coordinate with DC service provider \\\\r\\\\n• Perform routine inspections rack interfaces for leakage or degradation risks.\\\\r\\\\n• Support emergency containment and isolation procedures in case of leak or system malfunction events.\\\\r\\\\n• Coordinate with OEM specialists during major maintenance, firmware updates, or system upgrades.\\\\r\\\\n• Monitor cooling performance metrics ensuring high-density racks maintain required thermal stability levels.\\\\r\\\\n• Maintain detailed operational logs, incident records, and maintenance documentation.\\\\r\\\\n• Participate in emergency drills and high-density workload readiness exercises.\\\\r\\\\nQualifications\\\\r\\\\n• Diploma or bachelor’s degree in mechanical, HVAC, or Thermal Engineering discipline.\\\\r\\\\n• 5–12 years’ experience in cooling O&M with exposure to liquid cooling systems preferred.\\\\r\\\\n• Strong understanding of chilled water systems and liquid loop distribution architectures.\\\\r\\\\n• Experience working in high-density or AI-enabled DC environments preferred.\\\\r\\\\n• Knowledge of fluid safety handling and leak response protocols required

Key Responsibilities

Job Responsibilities : • Own and manage shift-level operations ensuring 24x7 service availability and adherence to SLA/KPI targets • Act as the primary escalation point for incidents (P1/P2/P3) and ensure timely response and resolution • Monitor liquid cooling systems including CDUs, piping loops, pumps, and rack-level cooling distribution units on a 24x7 basis. • Activities including coolant quality checks, pressure verification, and leak detection validation. • Respond to liquid cooling alarms including pressure drops, flow inconsistencies, and temperature deviation events and coordinate with DC service provider • Perform routine inspections rack interfaces for leakage or degradation risks. • Support emergency containment and isolation procedures in case of leak or system malfunction events. • Coordinate with OEM specialists during major maintenance, firmware updates, or system upgrades. • Monitor cooling performance metrics ensuring high-density racks maintain required thermal stability levels. • Maintain detailed operational logs, incident records, and maintenance documentation. • Participate in emergency drills and high-density workload readiness exercises.

Skill Requirements

Skill Requirement : • Diploma or bachelor’s degree in mechanical, HVAC, or Thermal Engineering discipline. • 5–12 years’ experience in cooling O&M with exposure to liquid cooling systems preferred. • Strong understanding of chilled water systems and liquid loop distribution architectures. • Experience working in high-density or AI-enabled DC environments preferred. • Knowledge of fluid safety handling and leak response protocols required

Other Requirements

NA

#body.unify div.unify-button-container .unify-apply-now: focus, #body.unify div.unify-button-container .unify-apply-#body.unify div.unify-button-container .unify-apply-now: focus, #body.unify div.unify-button-container .unify-apply-

Weitere interessante Jobs

68 Jobs
Frankfurt am Main
Vollzeit
Jobrad
Urlaub >= 30

Ref-Nr: 226000028173

16.06.2026

IT System Expert Network (m/w/d)

Soluvia IT-Services GmbH

Soluvia IT-Services GmbH
Kiel, Offenbach am Main, Mannheim
Vollzeit
Nachhaltiger Arbeitgeber
Flexible Arbeitszeiten
Home-Office

Ref-Nr: 226000020604

12.06.2026

Erhalte die neuesten Jobs für diese Suche kostenlos per E-Mail

Ratingen, Braunschweig, Frankfurt am Main, Hamburg, Berlin
Vollzeit
Weiterbildungen
Flexible Arbeitszeiten
Jobrad
Home-Office

Ref-Nr: YF-42554

22.06.2026

Systemadministrator (m/w/d)

Versorgungswerk der Landesärztekammer Hessen

Versorgungswerk der Landesärztekammer Hessen
Frankfurt am Main
Vollzeit
Weiterbildungen
Kinderbetreuung
Flexible Arbeitszeiten
4

Ref-Nr: 226000021041

18.06.2026

Senior Real Estate Manager (m/w/d)

GRR GARBE Retail Real Estate GmbH

GRR GARBE Retail Real Estate GmbH
Hamburg, Frankfurt am Main, Köln, Nürnberg
70.000 - 80.000 €/Jahr
Vollzeit
Flexible Arbeitszeiten
Berufsunfähigkeitsversicherung
Jobrad
3

Ref-Nr: YF-43762

24.06.2026